Roof Glazing Replacement at Shenley Brook School, Milton Keynes
Revitalising Educational Spaces: The Shenley Brook School Project
Shenley Brook School in Milton Keynes faced a pressing issue with their existing self-supporting curved Ridgelight. The constant leaks, attributed by a poor transom design, demanded a comprehensive solution. We answered the call and introduced our Skyline box glazing system, a game-changer that incorporated our unique structural ridge member. This robust addition transformed the Ridgelight into a far more weatherproof and dependable structure.
A Breath of Fresh Air: Fire Safety and Ventilation
In a commitment to safety, we provided ten automatic opening ventilators (AOV’s), complying with the stringent BS EN12101 harmonized European standard for smoke and heat control. These measures were essential to ensure that, in the unfortunate event of a fire, smoke dispersion was efficient and lives were protected. The safety of building users was of paramount importance.
Durability and Security: Double Glazed Units
We undertook the task of glazing the 280m² curved opening with double glazed units to compliment our Skyline box system. This strategic choice included 6mm Clear Toughened outer panes and 8.8mm Low emissive Class A laminated inner panes, culminating in a non-fragile assembly compliant with CWCT TN66 & TN 67 standards. This configuration not only enhances the safety of occupants but also ensures the well-being of maintenance personnel who regularly access the roof for essential upkeep.
Precision in Design and Surveying
The complex curved design of the project left no room for inaccuracies. Design and surveying operations had to be flawlessly executed. Fortunately, they were, thanks to our meticulous approach. This precision paved the way for a seamless installation, performed by our experienced and directly employed Installation Team.
Result: A Future Full of Light and Safety
The new installation at Shenley Brook School is not just a remedy for leaks; it’s a transformative addition. This revitalised space now boasts thermal efficiency, security, and, above all, an abundance of natural daylight. The future of educational excellence at Shenley Brook School is brighter, safer, and more sustainable than ever before.
This case study emphasises our commitment to elevating educational environments, ensuring that they remain conducive to learning and safety for years to come.
Testimonial ~ Simon Harding, Project Manager at M&J Group
“The Shenley Brook School project represented a critical transformation for educational spaces, and Standard Patent Glazing played a pivotal role in delivering a comprehensive solution.
The School encountered significant challenges with their existing curved Ridgelight, which had been plagued by persistent leaks attributed to an inherent flaw in the transom design. In response, Standard Patent Glazing introduced our innovative Skyline box glazing system, featuring the incorporation of our unique structural ridge member. This robust addition not only successfully addressed the weatherproofing issues but also ensured the establishment of a reliable structure with long-lasting performance.
Emphasising the utmost importance of safety, Standard Patent Glazing provided ten automatic opening ventilators (AOV’s) that strictly adhered to the rigorous BS EN12101 standard for smoke and heat control. This critical measure was indispensable in enhancing fire safety and guaranteeing the effective dispersal of smoke during emergency situations, thereby prioritising the safety and well-being of all building occupants. We extend our commendations to Standard Patent Glazing for their exceptional delivery and wholeheartedly recommend their comprehensive turnkey daylighting solutions to any prospective client in need of a trusted and reliable partner.”